ADIC FCR200 Spécifications Page 111

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 140
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 110
Fibre Channel Interface and Commands B-5
Report LUNs Command
In SCC mode, the FCR200 supports the Report LUNs
command. The Report LUNs command will return a list of
Logical Unit Numbers that can receive commands. The format
of the report LUNs command is as follows:
Table B-2 Report LUN Command
Bits
Bytes
76543210
0 Operation Code (0xA0)
1 Reserved
2 Reserved
3 Reserved
4 Reserved
5 Reserved
6
:
9
(MSB)
Allocation Length
(LSB)
10 Reserved
11 Code Byte
Table B-3 Report LUN Parameter List
Bits
Bytes
76543210
0
:
3
(MSB)
LUN List Length
(LSB)
4 Reserved
5 Reserved
6 Reserved
7 Reserved
LUN List